B
- Bad sector
A bad sector is a small block on a disk that the device can no longer read or write reliably.
C
- Clean room
A clean room is a workspace with filtered air, used when a hard disk drive has to be opened so dust does not settle on the platters.
D
- Degraded array
A degraded array is a RAID array that has lost one or more member disks but can still serve data from the disks that remain.
- Disk imaging
Disk imaging is making a sector-by-sector copy of a storage device so later work is done on the copy, not on the original.
E
- Encryption
Encryption is the process of turning readable data into ciphertext with an algorithm and a key, so that only someone with the right key can turn it back.
F
- Factory reset
A factory reset is an option that returns a phone, tablet or computer to the state it left the factory in, removing your apps, settings and, usually, your data.
- File system
A file system is the method a computer uses to organise files and folders on a volume, and to record where each file's data is stored.
H
- Hard disk drive (HDD)
A hard disk drive (HDD) is a storage device that records data magnetically on spinning platters and reads it with heads that fly just above the surface.
- Head crash
A head crash is physical contact between a hard disk drive's read/write heads and the magnetic platter surface.
- Hot spare
A hot spare is a disk installed in an array and kept powered and idle, ready to replace a failed disk and become the target of a rebuild without anyone swapping hardware.
L
- Logical failure
A logical failure is a problem in the file system, the partition, or the files themselves, while the storage hardware still works.
P
- Parity
Parity is a value calculated from a set of data blocks and stored with them, so that any one missing block can be worked out again from the others.
- Physical failure
A physical failure is damage to the storage hardware itself, such as the heads, the motor, the circuit board, or the platters.
R
- RAID 1
RAID 1 is a way of storing the same data on two or more disks at once, so the array can still be read if one of them fails. It is also called mirroring.
- RAID 5
RAID 5 is a way of storing data across at least three disks so the set can still be read after any one disk fails. RAID means redundant array of independent disks.
- RAID 6
RAID 6 is a way of storing data across several disks with two independent sets of parity, so the array keeps working and loses no data if any two disks fail.
- RAID parameters
RAID parameters are the settings that say how an array lays data out across its disks: the RAID level, the chunk (strip) size, the disk order, the parity layout and the data offset.
- Rebuild
A rebuild is the process where a RAID array recreates all the data from a failed disk and writes it onto a replacement disk, using the disks that remain.
S
- Solid-state drive (SSD)
A solid-state drive (SSD) is a storage device that keeps data in solid-state electronics, usually flash memory, instead of on spinning magnetic platters.
- Stripe size
Stripe size is the amount of data in one full stripe of a RAID array: the size of one chunk multiplied by the number of data chunks in the stripe.
W
- Write hole
The write hole is a RAID fault where an interrupted write leaves a stripe’s data and parity out of step, so a later calculation of a missing block can return wrong data.